Product Details:
|
Refrigerant: | R22 | Tube Material: | SS316L |
---|---|---|---|
Type: | Stainless Steel Type | Cooling Capacity: | 18KW~4000KW |
Application: | Refrigeration Industry | Shell Material: | Carbon Steel |
High Light: | stainless steel shell and tube heat exchanger,U heat exchanger |
Tube Condensing Unit Anti Corrosion
Stainless Steel Heat Exchanger
Stainless steel heat exchanger and brass heat exchanger difference between the stainless steel heat
exchanger and brass heat exchanger difference between the stainless steel heat exchanger and brass
heat exchanger is not the biggest difference between the heat transfer performance, corrosion resistance
is good or bad, But the brass is more difficult than the stainless steel pipe fouling, which is not aware of
the Chinese people.
To give a simple example, foreign commercial boilers are not water treatment equipment, but life is up to
15 years. The reason is that although the water can also produce scale in the copper pipe wall, but it is
only flocculent scale, in this case, as long as the increase in water flow rate, scale can not precipitate
down. Second, it is heat transfer performance.
The thermal conductivity of copper is higher than that of stainless steel, so the heat transfer coefficient of
brass in the same shape is higher than that of stainless steel tube. So the evaporator in the evaporator
with the heat transfer tubes are basically made of copper.
Third, the strength of stainless steel than copper higher, so now we see the plate heat exchanger plate is
stainless steel, but the original plate is copper.
OIL COOLER
CAPACITY 3RT TO 40RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | |||||
D | T1 | T | A | C | E | ||||
QXCF3S4 | 3 | 1.134 | 114 | 635 | 721 | 75 | 140 | 70 | 23 |
QXCF5S5 | 5 | 1.189 | 140 | 635 | 721 | 75 | 165 | 70 | 33 |
QXCF8S6 | 8 | 3.024 | 168 | 762 | 858 | 90 | 185 | 92 | 49 |
QXCF10S6 | 10 | 3.780 | 168 | 953 | 1049 | 90 | 185 | 92 | 58 |
QXCF12S6 | 12 | 4.536 | 168 | 953 | 1049 | 90 | 185 | 92 | 62 |
QXCF15S6 | 15 | 5.670 | 168 | 1270 | 1366 | 100 | 185 | 92 | 75 |
Model | S (Oil vent) |
P1 (inlet/outlet oil vent) Copper pipe external diameter (inch) |
W (inlet/outlet water vent) |
FPT(inner pipe thread) | FPT(inner pipe thread) | ||
QXCF3S4 | 1/2 | 5/8 | 1 |
QXCF5S5 | 1/2 | 5/8 | 1-1/2 |
QXCF8S6 | 1/2 | 7/8 | 1-1/2 |
QXCF10S6 | 1/2 | 7/8 | 1-1/2 |
QXCF12S6 | 1/2 | 1-1/8 | 1-1/2 |
QXCF15S6 | 1/2 | 1-1/8 | 1-1/2 |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 40RT TO 70RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC40S10A | 40 | 15.12 | 273 | 1600 | 2053 | 120 | 360 | 150 | 350 | 240 | 204 | 31 |
QXC45S10A | 45 | 17.01 | 273 | 1600 | 2053 | 120 | 360 | 150 | 350 | 240 | 212 | 35 |
QXC50S10A | 50 | 18.90 | 273 | 2032 | 2485 | 120 | 360 | 150 | 350 | 240 | 240 | 38.5 |
QXC55S10A | 55 | 20.79 | 273 | 2032 | 2485 | 120 | 360 | 150 | 350 | 240 | 249 | 42.5 |
QXC60S10A | 60 | 22.68 | 273 | 2032 | 2485 | 120 | 360 | 150 | 350 | 240 | 256 | 46 |
QXC65S10A | 65 | 24.57 | 273 | 2032 | 2485 | 120 | 360 | 150 | 350 | 240 | 264 | 49.2 |
QXC70S10A | 70 | 26.46 | 273 | 2032 | 2485 | 120 | 360 | 150 | 350 | 240 | 270 | 53.5 |
Model | S (Vent) |
P (fluoride inlet) Copper pipe diameter (inch) |
L(fluoride outlet) Copper pipe diameter (inch) |
W (standard port) | W (optional port) |
FPT(inner pipe thread) | Male flange | Male flange | |||
QXC40S10A | 3/8 | 1-5/8 | 1-1/8 | DN65 | DN65 |
QXC45S10A | 3/8 | 1-5/8 | 1-1/8 | DN65 | DN65 |
QXC50S10A | 3/8 | 1-5/8 | 1-1/8 | DN65 | DN80 |
QXC55S10A | 3/8 | 1-5/8 | 1-1/8 | DN65 | DN80 |
QXC60S10A | 3/8 | 1-5/8 | 1-3/8 | DN65 | DN80 |
QXC65S10A | 3/8 | 1-5/8 | 1-3/8 | DN65 | DN80 |
QXC70S10A | 3/8 | 2-1/8 | 1-3/8 | DN80 | DN80 |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 110RT TO 200RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC110S12A | 110 | 41.58 | 325 | 2500 | 2966 | 150 | 406 | 180 | 350 | 240 | 411 | 83.5 |
QXC120S14A | 120 | 45.36 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 490 | 91 |
QXC130S14A | 130 | 49.15 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 506 | 98.5 |
QXC140S14A | 140 | 52.92 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 521 | 106 |
QXC150S14A | 150 | 56.70 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 536 | 113.5 |
QXC160S16A | 160 | 60.48 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 637 | 120.6 |
QXC180S16A | 180 | 68.04 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 667 | 135.5 |
QXC200S16A | 200 | 75.60 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 697 | 150.8 |
Model | S (Vent) |
P (fluoride inlet) Copper pipe diameter (inch) |
L(fluoride outlet) Copper pipe diameter (inch) |
W (standard port) | W (optional port) |
FPT(inner pipe thread) | Male flange | Male flange | |||
QXC110S12A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC120S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC130S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC140S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC150S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN125 |
QXC160S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC180S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC200S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |