Send Message
Home ProductsShell And Tube Heat Exchanger

Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type

Certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
I'm Online Chat Now

Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type

Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type
Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type

Large Image :  Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type

Product Details:
Place of Origin: CHINA
Brand Name: GREEFOUN
Certification: CE
Model Number: QXU165
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Packaging Details: Standard Export Package
Delivery Time: within 15days
Payment Terms: TT, L/C, Western Union
Supply Ability: 100000pieces/year

Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type

Description
Type: Water Cooled, Water Source Heat Pump Shell Material: Carbon Steel
Connection Type: Brass Brazing/loose Flange/tenon Surface Cooling Capacity: 18KW~3000KW
Refrigerating Medium: Tap/underground/river/sea Water, Brine, Glycol/sulfate Solution Refrigerant: R22/R134a/R407C/R410A
High Light:

tube and shell heat exchanger

,

shell tube heat exchanger

Tubular Heat Exchanger Shell and Tube

 

Water Cooling Type Evaporator

 

1), the heat exchanger should be the maximum working pressure of 1.5 times the water pressure test, the

 

steam part should not be less than the steam supply pressure plus 0.3MPa; hot water should not be less

 

than 0.4MPa. Under the test pressure, keep the pressure for 10 min.

 

2), shell and tube heat exchanger front should be left to remove the tube bundle space, that is, the head

 

of the wall or roof distance shall not be less than the length of the heat exchanger, equipment operating

 

operating channel width should not be less than 0.8m.

 

3), the installation of various types of valves and instruments should be easy to operate and observe the

 

height.

 

4), the upper part of the heater upper part (generally refers to the safety valve) to the lowest point of the

 

vertical structure of the vertical clearance should meet the requirements of installation testing, and not

 

less than 0.2m.

 

U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)

 

CAPACITY: 120KW TO 270KW

 

 

Models     QXU120S8 QXU135S8 QXU155S8 QXU185S10 QXU220S10 QXU270S10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 120 135 155 185 220 270
Kcal/h(×103 ) 103.2 116 133.3 159 180 232
Wn m3 /h 20.3 23.2 26.7 31.8 37.8 46.4
Wm m3 /h 25 28 30 41 43 65
Dpn bar 0.41 0.44 0.37 0.36 0.43 0.42

 

Models QXU120S8 QXU135S8 QXU155S8 QXU185S10 QXU220S10 QXU270S10
Dimension(mm) A 1815 2115 2315 2320 2654 2654
B 219 219 219 273 273 273
C 180 180 180 200 234 234
D 1530 1830 2030 2000 2280 2280
E 240 240 240 300 300 300
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 80 80 80 100 100 100
D1(mm) 35 35 35 35 35 35
D2(mm) 54 54 67 67 80 80
P(kg) 145 155 163 232 279 289

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR

 

CAPACITY: 310KW TO 680KW

 

Models     RE310S10 RE360S12 RE420S12 RE470S12 RE540S14 RE620S14 RE680S14

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 310 360 420 470 540 620 680
Kcal/h(×103 ) 267 317 361 404 464 533 585
Wn m3 /h 53.3 62 72.2 80.8 93 107 116
Wm m3 /h 68 70 81.7 100 105 140 145
Dpn bar 0.43 0.43 0.35 0.46 0.41 0.47 0.49

 

Models RE310S10 RE360S12 RE420S12 RE470S12 RE540S14 RE620S14 RE680S14
Dimension(mm) A 140 140 150 150 150 170 170
B 273 273 325 325 355 377 377
C 2500 1690 2400 1500 2690 2690 2860
D 360 360 406 406 440 460 460
E 370 370 380 380 400 400 400
F 2586 2586 2488 2586 2776 2776 2946
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 100 100 125 125 125 150 150
D1(mm) 35 35 42 42 42 42 42
D2(mm) 67 67 80 80 90 90 90
P(kg) 296 380 398 442 459 654 669

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

CONDENSER SERIES SINGLE CIRCUIT 

 

CAPACITY: 75RT TO 100RT

 

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC75S12A 75 28.350 325 2032 2485 120 360 180 350 240 335 57.2
QXC80S12A 80 30.240 325 2032 2485 120 406 180 350 240 343 61
QXC85S12A 85 32.130 325 2032 2485 120 406 180 350 240 350 64.1
QXC90S12A 90 34.020 325 2032 2485 120 406 180 350 240 364 68
QXC95S12A 95 35.910 325 2032 2485 120 406 180 350 240 372 72.1
QXC100S12A 100 37.800 325 2500 2966 120 406 180 350 240 379 76

 

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port) W (optional port)
FPT(inner pipe thread) Male flange Male flange
QXC75S12A 3/8 2-1/8 1-3/8 DN80 DN100
QXC80S12A 3/8 2-1/8 1-3/8 DN80 DN100
QXC85S12A 3/8 2-5/8 1-3/8 DN100 DN100
QXC90S12A 3/8 2-5/8 1-3/8 DN100 DN100
QXC95S12A 3/8 2-5/8 1-3/8 DN100 DN100
QXC100S12A 3/8 3-1/8 1-5/8 DN100 DN100

 

COMPANY IMAGE
 
Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type 0
 
COOPERATED CLENTS
Industrial Shell And Tube Heat Exchanger With Brass Brazing Connection Type 1

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)