Product Details:
|
Cooling Capacity: | 18KW~4000KW | Refrigerant: | R22/R134a/R407C/R410A |
---|---|---|---|
Refrigerating Medium: | Glycol/sulfate Solution | Shell Material: | Carbon Steel |
Application: | Cooling Industry | Product: | Evaporator / Condenser |
High Light: | flooded type evaporator,tube shell heat exchanger |
Tube Heat Exchanger Flooded Type
Evaporator for Water Chiller
Full-liquid evaporator and dry evaporator in the opposite way of operation, cold water through the heat
transfer tube, the refrigerant completely immersed in the heat transfer tube, after the heat transfer tube in
the evaporation.
There are many needle-like holes in the surface of the heat transfer tube of the full-liquid evaporator, and
the spiral protrusions on the inner surface of the tube reinforce the heat exchange on the
cold water side.
This is the same time to enhance the tube outside the boiling and tube heat transfer of the efficient heat
transfer tube, so that the heat transfer coefficient than the light pipe increased by about 5 times.
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(SINGLE CIRCUIT) CAPACITY: 350KW TO 650KW
Models | QX-350M | QX-370M | QX-410M | QX-460M | QX-530M | QX-570M | QX-650M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 350 | 370 | 410 | 460 | 530 | 570 | 650 | |
Heating capacity (KW) | 400 | 445 | 480 | 540 | 630 | 690 | 730 | ||
Wa | m3/h | 61 | 63.5 | 71 | 80 | 91.5 | 98.6 | 112.3 | |
Wb | m3/h | 76 | 80 | 88.5 | 100 | 114.3 | 123 | 141 | |
Dpn | bar | 0.53 | 0.55 | 0.51 | 0.52 | 0.55 | 0.60 | 0.61 |
Models | QX-350M | QX-370M | QX-410M | QX-460M | QX-530M | QX-570M | QX-650M | |
Dimension(mm) | A | 2050 | 2050 | 2050 | 2050 | 2350 | 2350 | 2540 |
A1 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | |
A2 | 350 | 350 | 380 | 380 | 380 | 380 | 380 | |
L1 | 2200 | 2200 | 2200 | 2200 | 2500 | 2500 | 2690 | |
B | 1140 | 1140 | 1300 | 1300 | 1300 | 1300 | 1300 | |
B1 | 600 | 600 | 680 | 680 | 680 | 680 | 680 | |
C1 | 808 | 808 | 870 | 870 | 870 | 870 | 870 | |
C2 | 808 | 808 | 870 | 870 | 870 | 870 | 870 | |
D1 | 355 | 355 | 426 | 426 | 426 | 426 | 426 | |
D2 | 426 | 426 | 480 | 480 | 480 | 480 | 480 | |
H1 | 280 | 280 | 300 | 300 | 300 | 300 | 300 | |
H2 | 240 | 240 | 260 | 260 | 260 | 260 | 260 | |
Inlet/Outlet (diameter) Connection |
a/b(DN) | 125 | 125 | 150 | 150 | 150 | 150 | 150 |
c1-2 (mm) | 35 | 35 | 35 | 35 | 42 | 42 | 42 | |
d1(mm) | 80 | 92 | 92 | 92 | 92 | 92 | 92 | |
d2(mm) | 54 | 67 | 67 | 67 | 67 | 80 | 80 | |
Corresponding external oil | Volume (L) | 45 | 50 | 55 | 60 | 65 | 70 | 75 |
Weight | P (KG) | 451 | 580 | 690 | 786 | 920 | 1028 | 1150 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(SINGLE CIRCUIT) CAPACITY: 700KW TO 1800KW
Models | QX-700M | QX-820M | QX-950M | QX-1100M | QX-1300M | QX-1500M | QX-1800M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 700 | 820 | 950 | 1100 | 1300 | 1500 | 1800 | |
Heating capacity (KW) | 810 | 950 | 1120 | 1350 | 1625 | 1875 | 2250 | ||
Wa | m3/h | 121 | 141.5 | 164 | 190 | 224 | 258.5 | 310 | |
Wb | m3/h | 151 | 177 | 205 | 237 | 280 | 323 | 387 | |
Dpn | bar | 0.63 | 0.65 | 0.68 | 0.72 | 0.76 | 0.79 | 0.86 |
Models | QX-700M | QX-820M | QX-950M | QX-1100M | QX-1300M | QX-1500M | QX-1800M | |
Dimension(mm) | A | 2710 | 2710 | 2710 | 2710 | 2710 | 2850 | 3050 |
A1 | 500 | 500 | 550 | 550 | 550 | 550 | 550 | |
A2 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | |
L1 | 2860 | 2860 | 2860 | 2860 | 2860 | 3000 | 3200 | |
B | 1420 | 1420 | 1580 | 1580 | 1670 | 1670 | 1670 | |
B1 | 740 | 740 | 820 | 820 | 860 | 860 | 860 | |
C1 | 920 | 920 | 1003 | 1003 | 1053 | 1053 | 1053 | |
C2 | 920 | 920 | 1003 | 1003 | 1053 | 1053 | 1053 | |
D1 | 480 | 480 | 566 | 566 | 616 | 616 | 616 | |
D2 | 530 | 530 | 616 | 616 | 666 | 666 | 666 | |
H1 | 350 | 350 | 420 | 420 | 420 | 420 | 420 | |
H2 | 280 | 280 | 380 | 380 | 420 | 420 | 420 | |
Inlet/Outlet (diameter) Connection |
a/b(DN) | 200 | 200 | 250 | 250 | 250 | 250 | 250 |
c1-2 (mm) | 42 | 42 | 42 | 42 | 54 | 54 | 54 | |
d1(mm) | 92 | 105 | 105 | 105 | 105 | 105 | 105 | |
d2(mm) | 80 | 80 | 80 | 92 | 92 | 92 | 92 | |
Corresponding external oil | Volume (L) | 85 | 100 | 110 | 160 | 200 | 240 | 300 |
Weight | P (KG) | 1360 | 1580 | 1790 | 1930 | 2270 | 2480 | 2660 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(DOUBLE CIRCUIT) CAPACITY: 800KW TO 2200KW
Models | QX-800M | QX-950M | QX-1200M | QX-1380M | QX-1600M | QX-1900M | QX-2200M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 800 | 960 | 1200 | 1380 | 1600 | 1900 | 2200 | |
Heating capacity (KW) | 950 | 1140 | 1400 | 1650 | 2000 | 2380 | 2650 | ||
Wa | m3/h | 138 | 165.5 | 207 | 238 | 276 | 327.5 | 379 | |
Wb | m3/h | 192 | 206 | 259 | 297 | 344 | 400 | 473 | |
Dpn | bar | 0.71 | 0.73 | 0.75 | 0.76 | 0.79 | 0.82 | 0.84 |
Models | QX-800M | QX-950M | QX-1200M | QX-1380M | QX-1600M | QX-1900M | QX-2200M | |
Dimension(mm) | A | 3909 | 3909 | 3909 | 3909 | 4245 | 4245 | 4245 |
A1 | 450 | 500 | 500 | 500 | 500 | 500 | 500 | |
A2 | 360 | 400 | 400 | 400 | 400 | 400 | 400 | |
L1 | 2032 | 2032 | 2032 | 2032 | 2200 | 2200 | 2200 | |
B | 1340 | 1440 | 1470 | 1470 | 1470 | 1570 | 1570 | |
B1 | 690 | 740 | 755 | 755 | 755 | 805 | 805 | |
C1 | 925 | 975 | 1008 | 1008 | 1008 | 1058 | 1058 | |
C2 | 925 | 975 | 1008 | 1008 | 1008 | 1058 | 1058 | |
D1 | 426 | 480 | 480 | 480 | 480 | 530 | 530 | |
D2 | 480 | 530 | 566 | 566 | 566 | 616 | 616 | |
H1 | 300 | 350 | 350 | 350 | 350 | 350 | 350 | |
H2 | 260 | 280 | 280 | 280 | 280 | 350 | 350 | |
Inlet/Outlet (diameter) Connection |
a/b(DN) | 150 | 200 | 200 | 200 | 200 | 200 | 200 |
c1-4 (mm) | 35 | 42 | 42 | 42 | 42 | 42 | 42 | |
d1-2(mm) | 92 | 92 | 92 | 92 | 92 | 92 | 105 | |
D3-4(mm) | 67 | 67 | 67 | 80 | 80 | 80 | 80 | |
Corresponding external oil | Volume (L) | 90*2 | 95*2 | 100*2 | 110*2 | 130*2 | 160*2 | 180*2 |
Weight | P (KG) | 1745 | 2006 | 2570 | 2780 | 3140 | 3480 | 3610 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
COOPERATED CLENTS
Contact Person: Mrs. Nichole Deng
Tel: 15527011936
Fax: 86-27-8337-2527