Product Details:
|
Refrigerant: | R22 | Heat Exchange Tube: | SS316L |
---|---|---|---|
Type: | Shell And Tube Type | Cooling Capacity: | 18KW~4000KW |
Connection: | Loose Flange | Application: | Cooling Industry |
High Light: | shell tube evaporator,horizontal tube evaporator |
Marine Refrigeration Shell and Tube Evaporator
Water Cooled Heat Exchanger
Marine Refrigeration Shell and Tube Evaporator Water Cooled Heat Exchanger is suitable for water
cooled unit, water source heat pump, air cooled pump and air cooled heat pump unit.
The product is applying for refrigerants of R22, R134a, R407C and R410A etc.
The referigerating medium is for tap water, underground water, river water and sea water or brine, water
and glycol solution, sulfate solution, etc.
For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,
etc.
The shell raw material mainly are seamless steel tube, stainless steel pipe.
1, Heat exchange tube: four main tube type.
(1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.
(2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.
(3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry
evaporator.
(4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry
evaporator.
2, shell raw material:
There are two of the major materials:
(1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.
(2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than
40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.
3, Introduction:
(1) The product is applicable to water chiller units, water source heat pump units etc.
(2) Suitable refrigerants are R22, R134a, R407C, R410A etc.
(3) Apply load cold agent for tap water, underground water, river water and sea water or brine, water and
glycol solution, sulfate solution, etc.
(4) For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel
tube, etc. Shell using seamless steel pipe, stainless steel tube, etc.
4, Heat exchange tube: two main specifications.
(1) ∅ within 5/8 "efficient copper pipe outside screw wing, ∅ 5/8" stainless steel pipe.
(2) the ∅ 3/4 "inside outside screw wing efficient copper tube, ∅ 3/4" stainless steel pipe
5, Main material, the shell of 20 # seamless steel pipe, stainless steel pipe.
Self-developed products include dry type spiral baffle plate evaporator, flooded evaporator, built-in oil
separator condenser, sea water condenser, stainless steel heat exchanger, oil cooler, oil separator, gas-
liquid separator and liquid accumulator among others.
U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)
CAPACITY: 120KW TO 270KW
Models | QXU120S8 | QXU135S8 | QXU155S8 | QXU185S10 | QXU220S10 | QXU270S10 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C |
Qn | KW | 120 | 135 | 155 | 185 | 220 | 270 |
Kcal/h(×103 ) | 103.2 | 116 | 133.3 | 159 | 180 | 232 | ||
Wn | m3 /h | 20.3 | 23.2 | 26.7 | 31.8 | 37.8 | 46.4 | |
Wm | m3 /h | 25 | 28 | 30 | 41 | 43 | 65 | |
Dpn | bar | 0.41 | 0.44 | 0.37 | 0.36 | 0.43 | 0.42 |
Models | QXU120S8 | QXU135S8 | QXU155S8 | QXU185S10 | QXU220S10 | QXU270S10 | |
Dimension(mm) | A | 1815 | 2115 | 2315 | 2320 | 2654 | 2654 |
B | 219 | 219 | 219 | 273 | 273 | 273 | |
C | 180 | 180 | 180 | 200 | 234 | 234 | |
D | 1530 | 1830 | 2030 | 2000 | 2280 | 2280 | |
E | 240 | 240 | 240 | 300 | 300 | 300 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 80 | 80 | 80 | 100 | 100 | 100 |
D1(mm) | 35 | 35 | 35 | 35 | 35 | 35 | |
D2(mm) | 54 | 54 | 67 | 67 | 80 | 80 | |
P(kg) | 145 | 155 | 163 | 232 | 279 | 289 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 110RT TO 200RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC110S12A | 110 | 41.58 | 325 | 2500 | 2966 | 150 | 406 | 180 | 350 | 240 | 411 | 83.5 |
QXC120S14A | 120 | 45.36 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 490 | 91 |
QXC130S14A | 130 | 49.15 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 506 | 98.5 |
QXC140S14A | 140 | 52.92 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 521 | 106 |
QXC150S14A | 150 | 56.70 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 536 | 113.5 |
QXC160S16A | 160 | 60.48 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 637 | 120.6 |
QXC180S16A | 180 | 68.04 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 667 | 135.5 |
QXC200S16A | 200 | 75.60 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 697 | 150.8 |
Model | S (Vent) |
P (fluoride inlet) Copper pipe diameter (inch) |
L(fluoride outlet) Copper pipe diameter (inch) |
W (standard port) | W (optional port) |
FPT(inner pipe thread) | Male flange | Male flange | |||
QXC110S12A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC120S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC130S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC140S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC150S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN125 |
QXC160S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC180S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC200S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
COOPERATED CLENTS
Contact Person: Mrs. Nichole Deng
Tel: 15527011936
Fax: 86-27-8337-2527