Product Details:
|
Application: | Refrigeration Industry | Type: | Shell And Tube Type |
---|---|---|---|
Coolant: | Carbon Steel | Cooling Capacity: | 18KW~4000KW |
Heat Exchange Tube: | Stainless Steel | Refrigerant: | R404a |
High Light: | tube and shell heat exchanger,shell tube heat exchanger |
R404a Shell and Tube Evaporator
Heat Exchanger for Industrial Cooling
Dry type spiral baffle plate evaporator, flooded evaporator, built-in oil separator condenser, sea water
condenser, stainless steel heat exchanger, oil cooler
Dry evaporator refrigerant in the heat transfer tube through the cold water in the efficient heat transfer
tube outside the run, so the heat exchanger heat transfer efficiency is relatively low, the heat transfer
coefficient is only about 2 times the heat pipe heat transfer coefficient, but The advantage is easy to
return to oil, control is relatively simple, and the refrigerant charge is about full liquid type unit charge
amount of about 1/2 ~ 1/3 or so.
① refrigerant has a number of processes, such as the end of the cover can not produce a good solution,
so that the liquid into the next process is not uniform distribution, affecting the heat transfer effect;
② There is a leakage problem on the water side. As the outer edge of the baffle and the shell are
generally 1 ~ 3mm gap, there is about 2mm gap between the heat transfer tube and the water leakage.
Practice has proved that water leakage will cause the water side heat transfer coefficient reduced by 20%
to 30%, the total heat transfer coefficient decreased by 5% to 15%.
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(DOUBLE CIRCUIT) CAPACITY: 800KW TO 2200KW
Models | QX-800M | QX-950M | QX-1200M | QX-1380M | QX-1600M | Q-1900M | 2200M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerate capacity (KW) | 800 | 960 | 1200 | 1380 | 1600 | 1900 | 2200 | |
Heating capacity (KW) | 950 | 1140 | 1400 | 1650 | 2000 | 2380 | 2650 | ||
Wa | m3/h | 138 | 165.5 | 207 | 238 | 276 | 327.5 | 379 | |
Wb | m3/h | 192 | 206 | 259 | 297 | 344 | 400 | 473 | |
Dpn | bar | 0.71 | 0.73 | 0.75 | 0.76 | 0.79 | 0.82 | 0.84 |
Models | QX-800M | QX-950M | QX-1200M | QX-1380M | QX-1600M | QX-1900M | QX-2200M | |
Dimension(mm) | A | 3909 | 3909 | 3909 | 3909 | 4245 | 4245 | 4245 |
A1 | 450 | 500 | 500 | 500 | 500 | 500 | 500 | |
A2 | 360 | 400 | 400 | 400 | 400 | 400 | 400 | |
L1 | 2032 | 2032 | 2032 | 2032 | 2200 | 2200 | 2200 | |
B | 1340 | 1440 | 1470 | 1470 | 1470 | 1570 | 1570 | |
B1 | 690 | 740 | 755 | 755 | 755 | 805 | 805 | |
C1 | 925 | 975 | 1008 | 1008 | 1008 | 1058 | 1058 | |
C2 | 925 | 975 | 1008 | 1008 | 1008 | 1058 | 1058 | |
D1 | 426 | 480 | 480 | 480 | 480 | 530 | 530 | |
D2 | 480 | 530 | 566 | 566 | 566 | 616 | 616 | |
H1 | 300 | 350 | 350 | 350 | 350 | 350 | 350 | |
H2 | 260 | 280 | 280 | 280 | 280 | 350 | 350 | |
Inlet/Outlet (diameter) Connection |
a/b(DN) | 150 | 200 | 200 | 200 | 200 | 200 | 200 |
c1-4 (mm) | 35 | 42 | 42 | 42 | 42 | 42 | 42 | |
d1-2(mm) | 92 | 92 | 92 | 92 | 92 | 92 | 105 | |
D3-4(mm) | 67 | 67 | 67 | 80 | 80 | 80 | 80 | |
Corresponding external oil | Volume (L) | 90*2 | 95*2 | 100*2 | 110*2 | 130*2 | 160*2 | 180*2 |
Weight | P (KG) | 1745 | 2006 | 2570 | 2780 | 3140 | 3480 | 3610 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(DOUBLE CIRCUIT) CAPACITY: 2400KW TO 4000KW
Models | QX-2400M | QX-2650M | QX-2900M | QX-3200M | QX-3500M | 3750M | 4000M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerate capacity (KW) | 2400 | 2650 | 2900 | 3200 | 3500 | 3750 | 4000 | |
Heating capacity (KW) | 3000 | 3400 | 3750 | 3850 | 4000 | 4350 | 4500 | ||
Wa | m3/h | 413 | 456.5 | 499.6 | 550.6 | 602.3 | 646 | 688.5 | |
Wb | m3/h | 516 | 571 | 624 | 670 | 700 | 750 | 773 | |
Dpn | bar | 0.85 | 0.87 | 0.87 | 0.76 | 0.79 | 0.82 | 0.84 |
Models | QX-2400M | QX-2650M | QX-2900M | QX-3200M | QX-3500M | QX-3750M | Q-4000M | |
Dimension(mm) | A | 4845 | 4845 | 4845 | 4845 | 5035 | 5035 | 5035 |
A1 | 550 | 550 | 550 | 550 | 550 | 550 | 600 | |
A2 | 450 | 450 | 450 | 450 | 450 | 450 | 500 | |
L1 | 2500 | 2500 | 2500 | 2500 | 2690 | 2690 | 2690 | |
B | 1570 | 1570 | 1670 | 1670 | 1670 | 1670 | 1670 | |
B1 | 805 | 805 | 855 | 855 | 855 | 855 | 905 | |
C1 | 1058 | 1058 | 1108 | 1108 | 1108 | 1108 | 1158 | |
C2 | 1058 | 1058 | 1108 | 1108 | 1108 | 1108 | 1158 | |
D1 | 566 | 566 | 616 | 616 | 616 | 616 | 666 | |
D2 | 616 | 616 | 666 | 666 | 666 | 666 | 766 | |
H1 | 420 | 420 | 420 | 420 | 500 | 500 | 550 | |
H2 | 420 | 420 | 420 | 420 | 500 | 500 | 550 | |
Inlet/Outlet (diameter) Connection |
a/b(DN) | 250 | 250 | 250 | 250 | 250 | 250 | 300 |
c1-4 (mm) | 54 | 54 | 54 | 54 | 54 | 54 | 54 | |
d1-2(mm) | 105 | 105 | 105 | 105 | 105 | 105 | 105 | |
D3-4(mm) | 80 | 92 | 92 | 92 | 92 | 92 | 92 | |
Corresponding external oil | Volume (L) | 200*2 | 210*2 | 220*2 | 240*2 | 250*2 | 270*2 | 300*2 |
Weight | P (KG) | 3820 | 4255 | 4610 | 5080 | 5550 | 6070 | 6900 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 40RT TO 60RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||
D | T1 | T | A | C | E | |||||
QXC40S10 | 40 | 15.12 | 273 | 1600 | 1750 | 120 | 273 | 85 | 172 | 31 |
QXC45S10 | 45 | 17.01 | 273 | 1600 | 1750 | 120 | 273 | 85 | 180 | 35 |
QXC50S10 | 50 | 18.90 | 273 | 2032 | 2182 | 120 | 273 | 85 | 209 | 38.5 |
QXC55S10 | 55 | 20.79 | 273 | 2032 | 2182 | 120 | 273 | 85 | 217 | 42.5 |
QXC60S10 | 60 | 22.68 | 273 | 2032 | 2182 | 120 | 273 | 85 | 224 | 46 |
Model | S (Vent) |
P (fluoride inlet) Copper pipe diameter (inch) |
L(fluoride outlet) Copper pipe diameter (inch) |
W (standard port) | W (optional port) |
FPT(inner pipe thread) | FPT(inner pipe thread) | FPT(inner pipe thread) | |||
QXC40S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC45S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC50S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC55S10 | 3/8 | 1-5/8 | 1-3/8 | 3 | 2-1/2 |
QXC60S10 | 3/8 | 1-5/8 | 1-3/8 | 3 | 2-1/2 |
COMPANY IMAGE
COOPERATED CLENTS
Contact Person: Mrs. Nichole Deng
Tel: 15527011936
Fax: 86-27-8337-2527