Product Details:
|
Refrigerant: | R22/R134a/R407C/R410A | Heat Exchange Tube: | Red Copper/copper Nickel Alloy/aluminum Brass Tube Etc |
---|---|---|---|
Shell Material: | Carbon Steel | Cooling Capacity: | 18KW~4000KW |
Application: | Refrigeration Industry | System: | Single System |
High Light: | straight tube heat exchanger,dry type evaporator |
ASEM Stamp Industrial Shell Tube
Evaporator Dry Type Heat Exchanger
According to the type of cooling medium is different, the evaporator can be divided into two categories:
(1) cooling liquid refrigerant evaporator. Used to cool liquid refrigerant - water, saline or ethylene glycol
solution. This type of evaporator commonly used horizontal evaporator, riser evaporator and spiral tube
evaporator and so on.
(2) Evaporator for cooling air. This type of evaporator has a cooling pipe and a chillers.
First, the horizontal evaporator
1, its horizontal shell and tube condenser with the structure is basically similar. According to the liquid
supply can be divided into shell and tube evaporator and dry evaporator two. Horizontal shell and tube
evaporator is widely used in closed brine circulation system. Its main features are: compact structure,
liquid and heat transfer surface contact with high heat transfer coefficient.
But it needs to fill a large number of refrigerants, liquid column on the evaporation temperature will have a
certain impact. And when the brine concentration is reduced or the salt water pump is shut down for any
reason, the brine may be frozen in the tube.
If the refrigerant is freon, the freon dissolved lubricating oil is difficult to return to the compressor. Also
need to stop working when cleaning.
2, dry Flon evaporator main difference is: the refrigerant flow in the tube, while the refrigerant in the tube
outside the flow. After the flow of the freon liquid from the lower end of the side of the end into the
evaporator, after several processes from the top of the end of the cover, the refrigerant in the tube with
the flow and continue to evaporate, so the wall is part of the possession of steam, so , Its heat transfer
effect as full liquid.
However, it has no effect on the evaporative temperature of the liquid column and is better due to the
higher flow rate of Freon (≥4 m / s).
In addition, due to the tube filled with a large number of refrigerant, thereby slowing the risk of freezing.
This kind of evaporator refrigerant charge only enough liquid type 1/2 ~ l / 3 or less, so called "dry
evaporator".
STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR
CAPACITY: 750KW TO 1500KW
Models | RE750S14 | RE900S16 | RE1100S16 | RE1240S20 | RE1360S20 | RE1420S20 | RE1500S20 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C |
Qn | KW | 750 | 900 | 1100 | 1240 | 1360 | 1420 | 1500 |
Kcal/h(×103 ) | 700 | 862 | 983 | 1076 | 1169 | 1258 | 1367 | ||
Wn | m3 /h | 121 | 141 | 168 | 230 | 252 | 261 | 289 | |
Wm | m3 /h | 136 | 158 | 176 | 261 | 275 | 309 | 328 | |
Dpn | bar | 0.48 | 0.54 | 0.48 | 0.40 | 0.46 | 0.49 | 0.58 |
Models | RE750S14 | RE900S16 | RE1100S16 | RE1240S20 | RE1360S20 | RE1420S20 | RE1500S20 | |
Dimension(mm) | A | 170 | 170 | 170 | 190 | 190 | 190 | 190 |
B | 377 | 426 | 426 | 480 | 480 | 480 | 480 | |
C | 3000 | 2860 | 3000 | 2860 | 2860 | 3000 | 3500 | |
D | 460 | 530 | 530 | 600 | 600 | 600 | 600 | |
E | 400 | 450 | 450 | 500 | 500 | 500 | 550 | |
F | 3086 | 2984 | 3124 | 2984 | 2984 | 3124 | 3624 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 150 | 150 | 150 | 200 | 200 | 200 | 200 |
D1(mm) | 42 | 42 | 42 | 54(2) | 54(2) | 54(2) | 54(2) | |
D2(mm) | 92 | 92 | 92 | 108 | 108 | 108 | 108 | |
P(kg) | 706 | 753 | 808 | 863 | 921 | 992 | 1069 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
WATER TO WATER HEAT EXCHANGER
CAPACITY: 500KW TO 3500KW
Model | Capacity (KW) | Dimension (mm) | Weight (kg) | ||||||||
D | T1 | T | A | C | E | F | H1 | H2 | |||
QXWW35S10 | 500 | 273 | 1270 | 1723 | 120 | 360 | 150 | 100 | 350 | 240 | 200 |
QXWW50S10 | 700 | 273 | 1600 | 2053 | 120 | 360 | 150 | 100 | 350 | 240 | 237 |
QXWW70S12 | 1000 | 325 | 2032 | 2498 | 150 | 406 | 180 | 120 | 350 | 240 | 322 |
QXWW100S12 | 1500 | 325 | 2032 | 2498 | 150 | 406 | 180 | 120 | 350 | 240 | 367 |
QXWW140S14 | 2000 | 355 | 2500 | 3023 | 180 | 440 | 180 | 150 | 400 | 290 | 512 |
QXWW170S16 | 2500 | 426 | 2500 | 2951 | 180 | 530 | 260 | 150 | 310 | 310 | 693 |
QXWW200S16 | 3000 | 426 | 2500 | 2951 | 180 | 530 | 260 | 150 | 310 | 310 | 736 |
QXWW240S16 | 3500 | 426 | 2500 | 2951 | 180 | 530 | 260 | 150 | 310 | 310 | 795 |
Model | W1 | W2 | ||
Specification | Connection type | Specification | Connection type | |
QXWW35S10 | DN80 | male flange | DN80 | male flange |
QXWW50S10 | DN80 | male flange | DN80 | male flange |
QXWW70S12 | DN100 | male flange | DN100 | male flange |
QXWW100S12 | DN100 | male flange | DN100 | male flange |
QXWW140S14 | DN100 | male flange | DN100 | male flange |
QXWW170S16 | DN125 | male flange | DN125 | male flange |
QXWW200S16 | DN125 | male flange | DN125 | male flange |
QXWW240S16 | DN125 | male flange | DN125 | male flange |
CONDENSER SERIES DOUBLE MACHINE
CAPACITY: 50RT TO 200RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC50D10A | 50 | 18.9 | 273 | 953 | 2364 | 90 | 360 | 150 | 350 | 240 | 265 | 38.5 |
QXC60D10A | 60 | 22.68 | 273 | 953 | 2364 | 90 | 360 | 150 | 350 | 240 | 279 | 46 |
QXC70D12A | 70 | 26.46 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 359 | 53.5 |
QXC80D12A | 80 | 30.24 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 375 | 61 |
QXC100D12A | 100 | 37.80 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 409 | 76 |
QXC120D12A | 120 | 45.36 | 325 | 1270 | 3011 | 120 | 406 | 180 | 350 | 240 | 481 | 91 |
QXC140D14A | 140 | 52.92 | 355 | 1270 | 3018 | 120 | 440 | 200 | 350 | 240 | 553 | 106 |
QXC160D16A | 160 | 60.48 | 426 | 1600 | 3656 | 120 | 510 | 260 | 310 | 310 | 723 | 120.6 |
QXC200D16A | 200 | 75.60 | 426 | 1600 | 3656 | 120 | 510 | 260 | 310 | 310 | 777 | 150.8 |
Model | S (Vent) |
P (fluoride inlet) Copper pipe diameter (inch) |
L(fluoride outlet) Copper pipe diameter (inch) |
W (standard port) |
FPT(inner pipe thread) | Male flange | |||
QXC50D10A | 3/8 | 1-3/8 | 7/8 | DN65 |
QXC60D10A | 3/8 | 1-5/8 | 1-1/8 | DN65 |
QXC70D12A | 3/8 | 1-5/8 | 1-1/8 | DN80 |
QXC80D12A | 3/8 | 1-5/8 | 1-1/8 | DN80 |
QXC100D12A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC120D12A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC140D14A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC160D16A | 3/8 | 2-5/8 | 1-3/8 | DN125 |
QXC200D16A | 3/8 | 2-5/8 | 1-5/8 | DN125 |