Product Details:
|
Cooling Capacity: | 18KW~4000KW | Refrigerant: | R22/R134a/R407C/R410A |
---|---|---|---|
Refrigerating Medium: | Tap/underground/river/sea Water, Brine, Glycol/sulfate Solution | Shell Material: | Steel Pipe |
Application: | Cooling Industry | Heat Exchange Tube: | Red Copper |
High Light: | flooded type evaporator,tube shell heat exchanger |
Full Liquid Type Tube Heat Exchanger for Water Chiller System
It is widely used in ammonia refrigeration system and can also be used in Freon system.It has the
advantages of compact structure and small footprint, and can be used in closed loop, and can be used for
volatile cold storage.
Easy to accumulate oil. Refrigerant prone to freeze; refrigerant walking shell, water to run. The heat
transfer process is always between the liquid refrigerant and liquid water heat transfer between the
refrigerant gas directly from the compressor into the compressor, the heat transfer area is effectively used
to improve the unit's heat transfer efficiency.
Although full of liquid evaporator has a series of advantages, but there are the following shortcomings:
(1) large amount of refrigerant irrigation. For the more expensive freon, this shortcoming is even more
prominent.
(2) When the diameter of the evaporator shell is large, the evaporation temperature of the bottom liquid
will be improved by the static pressure of the liquid, which will reduce the heat transfer temperature
difference of the evaporator. The lower the evaporation temperature, the greater the effect. For freon
refrigerants, this effect is more pronounced because of its density.
(3) For the freon evaporator, the refrigerant dissolved in the refrigerant is difficult to discharge.
(4) When used as a marine refrigeration device, it is possible for the hull to swing the refrigerant liquid into
the compressor.
(SINGLE CIRCUIT) CAPACITY: 350KW TO 650KW
Models | QX-350M | QX-370M | QX-410M | QX-460M | QX-530M | QX-570M | QX-650M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 350 | 370 | 410 | 460 | 530 | 570 | 650 | |
Heating capacity (KW) | 400 | 445 | 480 | 540 | 630 | 690 | 730 | ||
Wa | m3/h | 61 | 63.5 | 71 | 80 | 91.5 | 98.6 | 112.3 | |
Wb | m3/h | 76 | 80 | 88.5 | 100 | 114.3 | 123 | 141 | |
Dpn | bar | 0.53 | 0.55 | 0.51 | 0.52 | 0.55 | 0.60 | 0.61 |
Models | QX-350M | QX-370M | QX-410M | QX-460M | QX-530M | QX-570M | QX-650M | |
Dimension(mm) | A | 2050 | 2050 | 2050 | 2050 | 2350 | 2350 | 2540 |
A1 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | |
A2 | 350 | 350 | 380 | 380 | 380 | 380 | 380 | |
L1 | 2200 | 2200 | 2200 | 2200 | 2500 | 2500 | 2690 | |
B | 1140 | 1140 | 1300 | 1300 | 1300 | 1300 | 1300 | |
B1 | 600 | 600 | 680 | 680 | 680 | 680 | 680 | |
C1 | 808 | 808 | 870 | 870 | 870 | 870 | 870 | |
C2 | 808 | 808 | 870 | 870 | 870 | 870 | 870 | |
D1 | 355 | 355 | 426 | 426 | 426 | 426 | 426 | |
D2 | 426 | 426 | 480 | 480 | 480 | 480 | 480 | |
H1 | 280 | 280 | 300 | 300 | 300 | 300 | 300 | |
H2 | 240 | 240 | 260 | 260 | 260 | 260 | 260 | |
Inlet/Outlet (diameter) |
a/b(DN) | 125 | 125 | 150 | 150 | 150 | 150 | 150 |
c1-2 (mm) | 35 | 35 | 35 | 35 | 42 | 42 | 42 | |
d1(mm) | 80 | 92 | 92 | 92 | 92 | 92 | 92 | |
d2(mm) | 54 | 67 | 67 | 67 | 67 | 80 | 80 | |
Corresponding external oil | Volume (L) | 45 | 50 | 55 | 60 | 65 | 70 | 75 |
Weight | P (KG) | 451 | 580 | 690 | 786 | 920 | 1028 | 1150 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C |
CONDENSER SERIES DOUBLE SYSTEM
CAPACITY: 50RT TO 200RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC50D10A | 50 | 18.9 | 273 | 953 | 2364 | 90 | 360 | 150 | 350 | 240 | 265 | 38.5 |
QXC60D10A | 60 | 22.68 | 273 | 953 | 2364 | 90 | 360 | 150 | 350 | 240 | 279 | 46 |
QXC70D12A | 70 | 26.46 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 359 | 53.5 |
QXC80D12A | 80 | 30.24 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 375 | 61 |
QXC100D12A | 100 | 37.80 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 409 | 76 |
QXC120D12A | 120 | 45.36 | 325 | 1270 | 3011 | 120 | 406 | 180 | 350 | 240 | 481 | 91 |
QXC140D14A | 140 | 52.92 | 355 | 1270 | 3018 | 120 | 440 | 200 | 350 | 240 | 553 | 106 |
QXC160D16A | 160 | 60.48 | 426 | 1600 | 3656 | 120 | 510 | 260 | 310 | 310 | 723 | 120.6 |
QXC200D16A | 200 | 75.60 | 426 | 1600 | 3656 | 120 | 510 | 260 | 310 | 310 | 777 | 150.8 |
Model | S (Vent) |
P (fluoride inlet) Copper pipe diameter (inch) |
L(fluoride outlet) Copper pipe diameter (inch) |
W (standard port) |
FPT(inner pipe thread) | Male flange | |||
QXC50D10A | 3/8 | 1-3/8 | 7/8 | DN65 |
QXC60D10A | 3/8 | 1-5/8 | 1-1/8 | DN65 |
QXC70D12A | 3/8 | 1-5/8 | 1-1/8 | DN80 |
QXC80D12A | 3/8 | 1-5/8 | 1-1/8 | DN80 |
QXC100D12A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC120D12A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
COOPERATED CLENTS