Product Details:
Place of Origin: CHINA
Brand Name: GREEFOUN
Certification: CE
Model Number: QX-370M
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Packaging Details: Standard export package
Delivery Time: within 15days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100000pieces per year

Water Cooling Flooded Heat Exchanger , Horizontal Straight Tube Heat Exchanger

Description
Cooling Capacity: 18KW~4000KW Refrigerant: R22/R134a/R407C/R410A
Refrigerating Medium: Tap/underground/river/sea Water, Brine, Glycol/sulfate Solution Shell Material: Steel Pipe
Application: Cooling Industry Heat Exchange Tube: Red Copper
High Light:

flooded type evaporator

,

tube shell heat exchanger

Full Liquid Type Tube Heat Exchanger for Water Chiller System​

 

It is widely used in ammonia refrigeration system and can also be used in Freon system.It has the

 

advantages of compact structure and small footprint, and can be used in closed loop, and can be used for

 

volatile cold storage.

 

Easy to accumulate oil. Refrigerant prone to freeze; refrigerant walking shell, water to run. The heat

 

transfer process is always between the liquid refrigerant and liquid water heat transfer between the

 

refrigerant gas directly from the compressor into the compressor, the heat transfer area is effectively used

 

to improve the unit's heat transfer efficiency.

 

Although full of liquid evaporator has a series of advantages, but there are the following shortcomings:

 

(1) large amount of refrigerant irrigation. For the more expensive freon, this shortcoming is even more

 

prominent.

 

(2) When the diameter of the evaporator shell is large, the evaporation temperature of the bottom liquid

 

will be improved by the static pressure of the liquid, which will reduce the heat transfer temperature

 

difference of the evaporator. The lower the evaporation temperature, the greater the effect. For freon

 

refrigerants, this effect is more pronounced because of its density.

 

(3) For the freon evaporator, the refrigerant dissolved in the refrigerant is difficult to discharge.

 

(4) When used as a marine refrigeration device, it is possible for the hull to swing the refrigerant liquid into

 

the compressor.

 

(SINGLE CIRCUIT) CAPACITY: 350KW TO 650KW
 

Models     QX-350M QX-370M QX-410M QX-460M QX-530M QX-570M QX-650M
Refrigerant R22 (or other environmental refrigerants)   Refrigerating capacity (KW) 350 370 410 460 530 570 650
Heating capacity (KW) 400 445 480 540 630 690 730
Wa m3/h 61 63.5 71 80 91.5 98.6 112.3
Wb m3/h 76 80 88.5 100 114.3 123 141
Dpn bar 0.53 0.55 0.51 0.52 0.55 0.60 0.61

 

Models QX-350M QX-370M QX-410M QX-460M QX-530M QX-570M QX-650M
Dimension(mm) A 2050 2050 2050 2050 2350 2350 2540
A1 400 400 450 450 450 450 450
A2 350 350 380 380 380 380 380
L1 2200 2200 2200 2200 2500 2500 2690
B 1140 1140 1300 1300 1300 1300 1300
B1 600 600 680 680 680 680 680
C1 808 808 870 870 870 870 870
C2 808 808 870 870 870 870 870
D1 355 355 426 426 426 426 426
D2 426 426 480 480 480 480 480
H1 280 280 300 300 300 300 300
H2 240 240 260 260 260 260 260

Inlet/Outlet (diameter)
Connection

a/b(DN) 125 125 150 150 150 150 150
c1-2 (mm) 35 35 35 35 42 42 42
d1(mm) 80 92 92 92 92 92 92
d2(mm) 54 67 67 67 67 80 80
Corresponding external oil Volume (L) 45 50 55 60 65 70 75
Weight P (KG) 451 580 690 786 920 1028 1150

Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water

Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C
Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C.

 

CONDENSER SERIES DOUBLE SYSTEM

 

CAPACITY: 50RT TO 200RT

 

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC50D10A 50 18.9 273 953 2364 90 360 150 350 240 265 38.5
QXC60D10A 60 22.68 273 953 2364 90 360 150 350 240 279 46
QXC70D12A 70 26.46 325 953 2377 90 406 180 350 240 359 53.5
QXC80D12A 80 30.24 325 953 2377 90 406 180 350 240 375 61
QXC100D12A 100 37.80 325 953 2377 90 406 180 350 240 409 76
QXC120D12A 120 45.36 325 1270 3011 120 406 180 350 240 481 91
QXC140D14A 140 52.92 355 1270 3018 120 440 200 350 240 553 106
QXC160D16A 160 60.48 426 1600 3656 120 510 260 310 310 723 120.6
QXC200D16A 200 75.60 426 1600 3656 120 510 260 310 310 777 150.8

 

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread) Male flange
QXC50D10A 3/8 1-3/8 7/8 DN65
QXC60D10A 3/8 1-5/8 1-1/8 DN65
QXC70D12A 3/8 1-5/8 1-1/8 DN80
QXC80D12A 3/8 1-5/8 1-1/8 DN80
QXC100D12A 3/8 2-1/8 1-3/8 DN100
QXC120D12A 3/8 2-1/8 1-3/8 DN100

 
Water Cooling Flooded Heat Exchanger , Horizontal Straight Tube Heat Exchanger 0

COOPERATED CLENTS
 
Water Cooling Flooded Heat Exchanger , Horizontal Straight Tube Heat Exchanger 1

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)