Send Message
Home ProductsShell And Tube Heat Exchanger

Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant

Certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
I'm Online Chat Now

Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant

Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant
Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant

Large Image :  Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant

Product Details:
Place of Origin: CHINA
Brand Name: GREEFOUN
Certification: CE
Model Number: QXU155D8
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Packaging Details: Standard Export Package
Delivery Time: within 15days
Payment Terms: TT, L/C, Western Union
Supply Ability: 100000pieces/year

Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant

Description
Refrigerant: R134a Color: Custom Made
Shell Material: Seamless/304,316Lstainless Steel Pipe Cooling Capacity: 18KW~3000KW
Heat Exchange Tube: Red Copper Cover Material: Carbon Steel
High Light:

tube and shell heat exchanger

,

u tube heat exchanger

Double Circuit Evaporator Shell and Tube

 

Heat Exchanger for Central Air Conditioning

 
Due to the internal and external fluid temperature is different, so the heat  exchanger shell and tube
 
bundle temperature is also different. If the temperature difference between the two, the heat exchanger
 
will produce a lot of thermal stress, resulting in pipe bending, fracture, or from the tube board pull.
 
Therefore, when the tube and the shell temperature difference exceeds 50 ℃, the need to take
 
appropriate compensation measures to eliminate or reduce thermal stress. According to
 
the compensation measures adopted, shell and tube heat exchanger can be divided into the following
 
main types:
 
① fixed tube plate heat exchanger tube at both ends of the tube plate and the shell into one, simple
 
structure, but only for hot and cold fluid temperature difference is not, and the shell does not need
 
mechanical cleaning when the heat transfer operation. When the temperature difference is slightly larger
 
and the shell pressure is not too high, the elastic compensation ring can be installed on the housing to
 
reduce the thermal stress.
 
(2) The tube sheet at the end of the tube bundle of the floating head heat exchanger can float freely and
 
completely eliminate the thermal stress; and the whole tube bundle can be extracted from the casing for
 
easy mechanical cleaning and maintenance. Floating head heat exchanger is widely used, but the
 
structure is more complex, higher cost.
 
③ U-tube heat exchanger each tube are bent into U-shaped, both ends were fixed in the same tube board
 
upper and lower areas, with the help of the box within the partition into the import and export of two rooms.
 
This heat exchanger completely eliminates thermal stress, the structure is simpler than the floating head,
 
but the pipe is not easy to clean.
 
④ eddy current hot film heat exchanger vortex hot film heat exchanger using the latest vortex heat film
 
heat transfer technology, by changing the fluid movement state to increase the heat transfer effect, when
 
the media through the vortex tube surface, the strong erosion of the pipe surface, Thermal efficiency. Up
 
to 10000W / m2 ℃. At the same time this structure to achieve a corrosion-resistant, high temperature,
 
high pressure, anti-fouling function. Other types of heat exchanger fluid channel for the fixed direction of
 
the flow form, the formation of heat transfer tube surface flow, convective heat transfer coefficient
 
decreases.

 

U SHAPED TUBE DRY EVAPORATOR (DOUBLE CIRCUIT)

 

CAPACITY: 120KW TO 310KW
 

Models  QXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270D10QXU310D10

Rated data
Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW120135155185220270310
Kcal/h(×103 )103.2116133.3159189232267
Wnm3 /h20.623.226.731.837.846.453.3
Wmm3 /h25283041436568
Dpnbar0.410.440.370.360.430.420.43

 

ModelsQXU120D8QXU135D8QXU155D8QXU185D10QXU220D10QXU270D10QXU310D10
Dimension(mm)A1815211523152320232026542654
B219219219219273273273
C200200200200234234234
D1530183020302000200022802280
E240240240300300300300
VentS11/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/2
ConnectionW(DN)89898989114114114
D1(mm)22222222353535
D2(mm)42424242545454
P(kg)145155163232255279296

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 
COMPANY IMAGE
 
Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant 0
 
COOPERATED CLENTS
Double Circuit Evaporator Shell Tube Heat Exchanger With R134a Refrigerant 1

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)