Product Details:
|
Refrigerant: | R22/R134a/R407C/R410A | Refrigerating Medium: | Tap/underground/river/sea Water, Brine, Glycol/sulfate Solution |
---|---|---|---|
Shell Material: | ABS | Cooling Capacity: | 8KW~4000KW |
Performance: | Anti-corrision, Anti-acid | Connection Type: | Brass Brazing/loose Flange/tenon Surface |
High Light: | shell and tube exchanger,high temperature heat exchanger |
Corrosion Resistant Tube Heat Exchanger Evaporator
Water - Cooled Heat Exchanger
Product advantages:
1. Internal tube: industrial 316L stainless steel tube, direct use in the strong acid bubble;
2. Shell: industrial corrosion-resistant chemical pipeline, white PP plastic;
3. Temperature can be -20 ℃ to 65 ℃ normal work;
4. open open maintenance, easy to clean;
5. Can be customized.
For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,
etc.
The shell raw material mainly are seamless steel tube, stainless steel pipe.
1, Heat exchange tube: four main tube type.
(1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.
(2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.
(3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry evaporator.
(4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry evaporator.
2, shell raw material:
There are two of the major materials:
(1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.
(2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than
40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.
3, interface:
CORROSION RESISTANT TUBE HEAT EXCHANGER EVAPORATOR
(DOUBLE MACHINE) CAPACITY: 320KW TO 680KW
Models | RE320D10 | RE360D12 | RE420D12 | RE470D12 | RE540D14 | RE620D14 | RE680D14 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C |
Qn | KW | 320 | 360 | 420 | 470 | 540 | 620 | 680 |
Kcal/h(×103 ) | 267 | 317 | 361 | 404 | 464 | 533 | 585 | ||
Wn | m3 /h | 53.3 | 62 | 72.2 | 80.8 | 93 | 107 | 116 | |
Wm | m3 /h | 68 | 70 | 81.7 | 100 | 105 | 140 | 145 | |
Dpn | bar | 0.43 | 0.43 | 0.35 | 0.46 | 0.41 | 0.47 | 0.49 |
Models | RE320D10 | RE360D12 | RE420D12 | RE470D12 | RE540D14 | RE620D14 | RE680D14 | |
Dimension(mm) | A | 140 | 140 | 150 | 150 | 150 | 170 | 170 |
B | 273 | 273 | 325 | 325 | 355 | 377 | 377 | |
C | 2500 | 1690 | 2400 | 1500 | 2690 | 2690 | 2860 | |
D | 360 | 360 | 406 | 406 | 440 | 460 | 460 | |
E | 370 | 370 | 380 | 380 | 400 | 400 | 400 | |
F | 2586 | 2586 | 2488 | 2586 | 2776 | 2776 | 2946 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 100 | 100 | 125 | 125 | 125 | 150 | 150 |
D1(mm) | 35 | 35 | 42 | 42 | 42 | 42 | 42 | |
D2(mm) | 67 | 67 | 80 | 80 | 90 | 90 | 90 | |
P(kg) | 296 | 380 | 398 | 442 | 459 | 654 | 669 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
CORROSION RESISTANT TUBE HEAT EXCHANGER EVAPORATOR
(DOUBLE MACHINE) CAPACITY: 2400KW TO 4000KW
Models | QX-2400M | QX-2650M | QX-2900M | QX-3200M | QX-3500M | QX-3750M | QX-4000M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 2400 | 2650 | 2900 | 3200 | 3500 | 3750 | 4000 | |
Heating capacity (KW) | 3000 | 3400 | 3750 | 3850 | 4000 | 4350 | 4500 | ||
Wa | m3/h | 413 | 456.5 | 499.6 | 550.6 | 602.3 | 646 | 688.5 | |
Wb | m3/h | 516 | 571 | 624 | 670 | 700 | 750 | 773 | |
Dpn | bar | 0.85 | 0.87 | 0.87 | 0.76 | 0.79 | 0.82 | 0.84 |
Models | QX-2400M | QX-2650M | QX-2900M | QX-3200M | QX-3500M | QX-3750M | QX-4000M | |
Dimension(mm) | A | 4845 | 4845 | 4845 | 4845 | 5035 | 5035 | 5035 |
A1 | 550 | 550 | 550 | 550 | 550 | 550 | 600 | |
A2 | 450 | 450 | 450 | 450 | 450 | 450 | 500 | |
L1 | 2500 | 2500 | 2500 | 2500 | 2690 | 2690 | 2690 | |
B | 1570 | 1570 | 1670 | 1670 | 1670 | 1670 | 1670 | |
B1 | 805 | 805 | 855 | 855 | 855 | 855 | 905 | |
C1 | 1058 | 1058 | 1108 | 1108 | 1108 | 1108 | 1158 | |
C2 | 1058 | 1058 | 1108 | 1108 | 1108 | 1108 | 1158 | |
D1 | 566 | 566 | 616 | 616 | 616 | 616 | 666 | |
D2 | 616 | 616 | 666 | 666 | 666 | 666 | 766 | |
H1 | 420 | 420 | 420 | 420 | 500 | 500 | 550 | |
H2 | 420 | 420 | 420 | 420 | 500 | 500 | 550 | |
Inlet/Outlet (diameter) Connection |
a/b(DN) | 250 | 250 | 250 | 250 | 250 | 250 | 300 |
c1-4 (mm) | 54 | 54 | 54 | 54 | 54 | 54 | 54 | |
d1-2(mm) | 105 | 105 | 105 | 105 | 105 | 105 | 105 | |
D3-4(mm) | 80 | 92 | 92 | 92 | 92 | 92 | 92 | |
Corresponding external oil | Volume (L) | 200*2 | 210*2 | 220*2 | 240*2 | 250*2 | 270*2 | 300*2 |
Weight | P (KG) | 3820 | 4255 | 4610 | 5080 | 5550 | 6070 | 6900 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |