Send Message
Home ProductsDry Heat Exchanger

Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit

Certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
I'm Online Chat Now

Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit

Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit
Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit

Large Image :  Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit

Product Details:
Place of Origin: CHINA
Brand Name: GREEFOUN
Certification: CE
Model Number: QXU95S8
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Packaging Details: Standard export package
Delivery Time: within 15days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100000pieces/year

Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit

Description
Refrigerant: R22/R134a/R407C/R410A Heat Exchange Tube: Red Copper/copper Nickel Alloy/aluminum Brass Tube Etc
Shell Material: Seamless/304,316Lstainless Steel Pipe Cooling Capacity: 18KW~3000KW
Application: Central Air Conditioning Unit System: Triple System
High Light:

chilled water heat exchanger

,

dry type evaporator

Central Air Conditioning Unit

 

Dry Type Evaporator Heat Exchanger

 

A central air conditioning unit shell and tube heat exchanger comprising a housing and an end cap, the

 

end cap being provided with a refrigerant inlet and a refrigerant outlet, the shell is a cylindrical structure

 

having one end opening, Wherein the housing is provided with a manifold orifice which separates the

 

housing into a first cavity and a second cavity, the first cavity end is provided with an inlet pipe, the

 

second chamber Body with copper tube bundle.

 

The shell-type heat exchanger of the central air conditioning unit of the utility model has the addition of

 

the orifice plate at the water inlet, reduces the local water velocity and reduces the impact on the copper

 

pipe, and the direction of the water enters from the direction perpendicular to the copper tube bundle

 

Direction, to avoid the direct flow of water into the brass, causing the copper tube fatigue deformation and

 

rupture; in the refrigerant inlet with a cooling plate, so that the refrigerant can even enter the end into the

 

liquid chamber, thus avoiding the Uneven distribution of refrigerant causes severe local heat transfer.

 

U SHAPED TUBE DRY EVAPORATOR (DOUBLE SYSTEM)

 

CAPACITY: 35KW TO 95KW

 

Models     QXU35D6 QXU47D6 QXU56D6 QXU65D8 QXU80D8 QXU95D8

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 35 47 56 65 80 95
Kcal/h(×103 ) 30.2 40.4 48.2 56.7 68.8 81.7
Wn m3 /h 6 8 9.6 11.4 13.8 16.4
Wm m3 /h 10 11.4 12 14.5 19 21
Dpn bar 0.27 0.41 0.35 0.39 0.42 0.46

 

Models QXU35D6 QXU47D6 QXU56D6 QXU65D8 QXU80D8 QXU95D8
Dimension(mm) A 1275 1407 1431 1431 1631 1781
B 168 168 168 168 219 219
C 107 107 161 161 200 200
D 1040 1190 1030 1180 1380 1530
E 200 200 200 240 240 240
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 50 50 50 50 65 65
D1(mm) 16 16 22 22 22 22
D2(mm) 22 22 35 35 35 35
P(kg) 72 78 88 93 125 136

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

U SHAPED TUBE DRY EVAPORATOR (DOUBLE CIRCUIT)

 

CAPACITY: 120KW TO 310KW

 

Models     QXU120D8 QXU135D8 QXU155D8 QXU185D10 QXU220D10 QXU270D10 QXU310D10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 120 135 155 185 220 270 310
Kcal/h(×103 ) 103.2 116 133.3 159 189 232 267
Wn m3 /h 20.6 23.2 26.7 31.8 37.8 46.4 53.3
Wm m3 /h 25 28 30 41 43 65 68
Dpn bar 0.41 0.44 0.37 0.36 0.43 0.42 0.43

 

Models QXU120D8 QXU135D8 QXU155D8 QXU185D10 QXU220D10 QXU270D10 QXU310D10
Dimension(mm) A 1815 2115 2315 2320 2320 2654 2654
B 219 219 219 219 273 273 273
C 200 200 200 200 234 234 234
D 1530 1830 2030 2000 2000 2280 2280
E 240 240 240 300 300 300 300
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 89 89 89 89 114 114 114
D1(mm) 22 22 22 22 35 35 35
D2(mm) 42 42 42 42 54 54 54
P(kg) 145 155 163 232 255 279 296

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)

 

CAPACITY: 120KW TO 270KW

 

Models     QXU120S8 QXU135S8 QXU155S8 QXU185S10 QXU220S10 QXU270S10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 120 135 155 185 220 270
Kcal/h(×103 ) 103.2 116 133.3 159 180 232
Wn m3 /h 20.3 23.2 26.7 31.8 37.8 46.4
Wm m3 /h 25 28 30 41 43 65
Dpn bar 0.41 0.44 0.37 0.36 0.43 0.42

 

Models QXU120S8 QXU135S8 QXU155S8 QXU185S10 QXU220S10 QXU270S10
Dimension(mm) A 1815 2115 2315 2320 2654 2654
B 219 219 219 273 273 273
C 180 180 180 200 234 234
D 1530 1830 2030 2000 2280 2280
E 240 240 240 300 300 300
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 80 80 80 100 100 100
D1(mm) 35 35 35 35 35 35
D2(mm) 54 54 67 67 80 80
P(kg) 145 155 163 232 279 289

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

 

Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit 0

 

COOPERATED CLENTS
 
Triple System U Type Dry Heat Exchanger For Central Air Conditioning Unit 1

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)