Send Message
Home ProductsDry Heat Exchanger

Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller

Certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
I'm Online Chat Now

Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller

Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller
Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller

Large Image :  Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller

Product Details:
Place of Origin: CHINA
Brand Name: GREEFOUN
Certification: CE
Model Number: QXU760S14
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Packaging Details: Standard export package
Delivery Time: within 15days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100000pieces/year

Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller

Description
Refrigerant: R22/R134a/R407C/R410A Refrigerating Medium: Tap/underground/river/sea Water, Brine, Glycol/sulfate Solution
Shell Material: Seamless Steel Pipe Cooling Capacity: 18KW~3000KW
Application: Cooling Industry Type: Water Cooled, Water Source Heat Pump
High Light:

straight tube heat exchanger

,

chilled water heat exchanger

Tube Shell Type Water Cooled Heat Exchanger

 

Evaporator for Screw Chiller

 

The refrigerant is completely evaporated in the tube and overheated to become a superheated gas, which

 

facilitates the automatic adjustment of the supply volume using the thermostatic expansion valve.

 

The refrigerants commonly used are R22, R134a, R407C, R410A and the like. Because the refrigerant

 

tube evaporation, as long as the tube flow rate of more than 4 m / s, you can put the tube of lubricants

 

back to the compressor, back to the oil convenient.

 

In the design, the shell side adopts the E-type structure (baffle type) specified by GB151 or TEMA. The

 

size of the baffle plate is 15% ~ 50% of the gap according to the physical properties of the refrigerant and

 

the flow rate. , The flow rate of the baffle notch is approximately equal to the flow rate of the refrigerant in

 

the transverse direction of the refrigerant. In order to ensure the heat transfer effect, the gap between the

 

baffle and the cylinder is smaller than or equal to GB151 or TEMA The minimum clearance, especially in

 

the case of low temperature, these gaps are particularly important, because in low temperature, the

 

refrigerant is generally high viscosity fluid, slow flow, thermal resistance is relatively increased, the gap

 

leakage is more obvious, so low temperature The case of the control of the gap must be more stringent.

 

The heat transfer tube adopts the internal strengthening and efficient heat transfer tube.

 

The inside of the heat transfer tube adopts the spiral groove type. Generally, there are 32 to 75 trenches,

 

which are mainly used to enhance the heat transfer effect inside the tube. But also do the corresponding

 

strengthening, the heat transfer tube according to the different refrigerant can be used copper T2, high

 

phosphor copper TP2, nickel copper BFe10-1-1, tin copper HSn70-1, aluminum and copper HA177-2 and

 

other materials.

 

The heat transfer tubes and tubesheets are generally connected by means of expansion joints. A set of

 

dispensers are normally provided at the inlet of the refrigerant for the equal distribution of the gas-liquid

 

mixture.

 

The dry evaporator is generally suitable for use in compressor refrigeration systems with displacement

 

less than 2000 m3 / h , It is preferable not to use this type of evaporator due to the uneven distribution of

 

the refrigerant in the large-scale system.


 

STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR

 

CAPACITY: 750KW TO 1500KW

 

Models     RE750S14 RE900S16 RE1100S16 RE1240S20 RE1360S20 RE1420S20 RE1500S20

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 750 900 1100 1240 1360 1420 1500
Kcal/h(×103 ) 700 862 983 1076 1169 1258 1367
Wn m3 /h 121 141 168 230 252 261 289
Wm m3 /h 136 158 176 261 275 309 328
Dpn bar 0.48 0.54 0.48 0.40 0.46 0.49 0.58

 

Models RE750S14 RE900S16 RE1100S16 RE1240S20 RE1360S20 RE1420S20 RE1500S20
Dimension(mm) A 170 170 170 190 190 190 190
B 377 426 426 480 480 480 480
C 3000 2860 3000 2860 2860 3000 3500
D 460 530 530 600 600 600 600
E 400 450 450 500 500 500 550
F 3086 2984 3124 2984 2984 3124 3624
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 150 150 150 200 200 200 200
D1(mm) 42 42 42 54(2) 54(2) 54(2) 54(2)
D2(mm) 92 92 92 108 108 108 108
P(kg) 706 753 808 863 921 992 1069

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

 

U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)

 

CAPACITY: 120KW TO 270KW

 

Models     QXU120S8 QXU135S8 QXU155S8 QXU185S10 QXU220S10 QXU270S10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

Qn KW 120 135 155 185 220 270
Kcal/h(×103 ) 103.2 116 133.3 159 180 232
Wn m3 /h 20.3 23.2 26.7 31.8 37.8 46.4
Wm m3 /h 25 28 30 41 43 65
Dpn bar 0.41 0.44 0.37 0.36 0.43 0.42

 

Models QXU120S8 QXU135S8 QXU155S8 QXU185S10 QXU220S10 QXU270S10
Dimension(mm) A 1815 2115 2315 2320 2654 2654
B 219 219 219 273 273 273
C 180 180 180 200 234 234
D 1530 1830 2030 2000 2280 2280
E 240 240 240 300 300 300
Vent S1 1/2 1/2 1/2 1/2 1/2 1/2
Outlet S2 1/2 1/2 1/2 1/2 1/2 1/2
Connection W(DN) 80 80 80 100 100 100
D1(mm) 35 35 35 35 35 35
D2(mm) 54 54 67 67 80 80
P(kg) 145 155 163 232 279 289

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

CONDENSER SERIES SINGLE CIRCUIT

 

CAPACITY: 40RT TO 70RT

 

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC40S10A 40 15.12 273 1600 2053 120 360 150 350 240 204 31
QXC45S10A 45 17.01 273 1600 2053 120 360 150 350 240 212 35
QXC50S10A 50 18.90 273 2032 2485 120 360 150 350 240 240 38.5
QXC55S10A 55 20.79 273 2032 2485 120 360 150 350 240 249 42.5
QXC60S10A 60 22.68 273 2032 2485 120 360 150 350 240 256 46
QXC65S10A 65 24.57 273 2032 2485 120 360 150 350 240 264 49.2
QXC70S10A 70 26.46 273 2032 2485 120 360 150 350 240 270 53.5

 

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port) W (optional port)
FPT(inner pipe thread) Male flange Male flange
QXC40S10A 3/8 1-5/8 1-1/8 DN65 DN65
QXC45S10A 3/8 1-5/8 1-1/8 DN65 DN65
QXC50S10A 3/8 1-5/8 1-1/8 DN65 DN80
QXC55S10A 3/8 1-5/8 1-1/8 DN65 DN80
QXC60S10A 3/8 1-5/8 1-3/8 DN65 DN80
QXC65S10A 3/8 1-5/8 1-3/8 DN65 DN80
QXC70S10A 3/8 2-1/8 1-3/8 DN80 DN80

 

Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller 0

 

COOPERATED CLENTS
 
Seamless Steel Pipe Dry Heat Exchanger Evaporator For Screw Chiller 1

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)