Home ProductsAir Cooled And Water Cooled Chillers

380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller

Certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
China Wuhan Qiaoxin Refrigeration Equipment CO., LTD certification
I'm Online Chat Now

380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller

380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller
380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller

Large Image :  380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller

Product Details:
Place of Origin: China
Certification: CE, ISO
Model Number: DC-RC40W
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD300-USD3000
Packaging Details: STANDARD EXPORT PACKAGE
Delivery Time: 15DAYS
Payment Terms: L/C, T/T, Western Union
Supply Ability: 800PCS PER YEAR

380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller

Description
Compressor Brand: Panasonic, Daikin, Copeland Electronic Components: Danfoss, Emerson, Siemens Etc
Condenser: Thickened Corrugated Window-opening Aluminum Fin With Copper Tubing Evaporator: Coil Evaporator/plate Heat Exchanger/shell And Tube
Temprature Control Range: 5-25degree Power Supply: 380v/50hz/3ph
High Light:

Water Cooled Chiller Heat Recovery Exchanger

,

Air Cooled Chiller Heat Recovery Exchanger

,

380V Chiller Exchanger

Chiller heat recovery exchanger evaporation for air cooled and water cooled chillers

 

The heat exchange tube uses copper pipe, nickel-copper alloy tubes, aluminum brass tube and stainless

 

steel tube as the material and the shell uses No.20 seamless steel tube and stainless steel tube.

 

Self-developed products include dry type spiral baffle plate evaporator, flooded evaporator, built-in oil

 

separator condenser, sea water condenser, stainless steel heat exchanger, oil cooler, oil separator, gas-

 

liquid separator and liquid accumulator.

 

1, Introduction:

 

(1) The product is applicable to water chiller units, water source heat pump units etc.

 

(2) Suitable refrigerants are R22, R134a, R407C, R410A etc.

 

(3) Apply load cold agent for tap water, underground water, river water and sea water or brine, water and

 

glycol solution, sulfate solution, etc.

 

(4) For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel

 

tube, etc. Shell using seamless steel pipe, stainless steel tube, etc.

 

2, Heat exchange tube: two main specifications.


(1) ∅ within 5/8 "efficient copper pipe outside screw wing, ∅ 5/8" stainless steel pipe.


(2) the ∅ 3/4 "inside outside screw wing efficient copper tube, ∅ 3/4" stainless steel pipe

 

3, Main material, the shell of 20 # seamless steel pipe, stainless steel pipe.


4, Interface:

 

CONDENSER SERIES SINGLE CIRCUIT

 

CAPACITY: 20RT TO 35RT

 

 

  
Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E
QXC20S8 20 7.560 219 1270 1380 90 238 113 110 15.8
QXC25S8 25 9.450 219 1600 1710 120 238 113 121 19.5
QXC30S8 30 11.340 219 1600 1710 120 238 113 134 23
QXC35S8 35 13.230 219 1600 1710 120 238 113 140 27.3

 

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port) W (optional port)
FPT(inner pipe thread) FPT(inner pipe thread) FPT(inner pipe thread)
QXC20S8 1/4 1-1/8 7/8 2-1/2 2
QXC25S8 1/4 1-1/8 7/8 2-1/2 2
QXC30S8 1/4 1-3/8 1-1/8 2-1/2 2
QXC35S8 1/4 1-5/8 1-1/8 2-1/2 2

 

CONDENSER SERIES DOUBLE CIRCUIT

 

CAPACITY: 50RT TO 200RT

 

Model Refrig. ton (RT) Refrig. ton (104kcal/h) Dimension (mm) Weight (kg) Max. water flow
D T1 T A C E H1 H2
QXC50D10A 50 18.9 273 953 2364 90 360 150 350 240 265 38.5
QXC60D10A 60 22.68 273 953 2364 90 360 150 350 240 279 46
QXC70D12A 70 26.46 325 953 2377 90 406 180 350 240 359 53.5
QXC80D12A 80 30.24 325 953 2377 90 406 180 350 240 375 61
QXC100D12A 100 37.80 325 953 2377 90 406 180 350 240 409 76
QXC120D12A 120 45.36 325 1270 3011 120 406 180 350 240 481 91
QXC140D14A 140 52.92 355 1270 3018 120 440 200 350 240 553 106
QXC160D16A 160 60.48 426 1600 3656 120 510 260 310 310 723 120.6
QXC200D16A 200 75.60 426 1600 3656 120 510 260 310 310 777 150.8

 

Model S (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread) Male flange
QXC50D10A 3/8 1-3/8 7/8 DN65
QXC60D10A 3/8 1-5/8 1-1/8 DN65
QXC70D12A 3/8 1-5/8 1-1/8 DN80
QXC80D12A 3/8 1-5/8 1-1/8 DN80
QXC100D12A 3/8 2-1/8 1-3/8 DN100
QXC120D12A 3/8 2-1/8 1-3/8 DN100
QXC140D14A 3/8 2-1/8 1-3/8 DN100
QXC160D16A 3/8 2-5/8 1-3/8 DN125
QXC200D16A 3/8 2-5/8 1-5/8 DN125

 

VERTICAL ACCUMULATOR

 

CAPACITY 10L TO 80L

 

Models L Dimension (mm) Kg
D A B H1 H2
QXR10L 10 273 220 220 300 350 21
QXR15L 15 273 220 220 400 450 26
QXR20L 20 325 280 280 400 450 35
QXR30L 30 355 300 300 450 500 47
QXR40L 40 355 300 300 600 650 58
QXR60L 60 426 360 360 600 650 76
QXR80L 80 426 360 360 600 850 97

 

Models S (pipe thread) P1 P2
FPT Pipe diameter (inch) Pipe diameter (inch)
QXR10L 3/8 7/8 7/8
QXR15L 3/8 1-1/8 1-1/8
QXR20L 3/8 1-3/8 1-3/8
QXR30L 3/8 1-3/8 1-3/8
QXR40L 3/8 1-3/8 1-3/8
QXR60L 3/8 1-5/8 1-5/8
QXR80L 3/8 1-5/8 1-5/8
 

380V Heat Recovery Exchanger For Air Cooled And Water Cooled Chiller 0

 

 

Contact Details
Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Contact Person: Mrs. Nichole Deng

Tel: 15527011936

Fax: 86-27-8337-2527

Send your inquiry directly to us (0 / 3000)

Other Products